TO: Chair and Members of the Design Review Committee
FROM: Anna Pehoushek, Assistant Community Development Director
1. Subject
title
Design Review No. 5070-22 and Minor Site Plan No. 1086-22, South Grand Street Second Unit, 515 S. Grand Street (Continued from 06/15/2022)
end
2. Summary
recommendation
Final determination by the Design Review Committee.
body
The applicant proposes to construct a new one and one half story, three-bedroom second unit on a property zoned Duplex Residential (R-2-6). The property is a contributing resource to the Old Towne Historic District. The project was continued by the Design Review Committee on June 15, 2022 for design revisions.
end
3. BACKGROUND INFORMATION
Applicant: Tom Aldrich, DSEA, Inc.
Owner: Mike and Alison Vukovich
Property Location: 515 S. Grand Street
General Plan Designation: Low Medium Density Residential (LMDR)
Zoning Classification: Duplex Residential (R-2-6)
Existing Development: 1,796 square foot one and one-half story single-family residence and 342 square foot detached garage (2,138 sq. ft. total)
Associated Application: None
Previous DRC Project Review: June 15, 2022
4. project description
The applicant proposes to construct a new one and one-half story three-bedroom, two bathroom duplex unit on a property zoned R-2-6. The property has an existing historic single-family residence and detached garage. The new unit has been designed with Craftsman-inspired details to relate to the existing residence. The original project proposal is described in Attachment 4 to this report. Since being presented to the Design Review Committee (DRC) in June the project has undergone revisions that are presented in Section 7 of this report.
Detailed plans and photographs are included as Attachment 2 of this report. The proposed work meets the development standards for the R-2-6 zoning district, including setbacks, open space, and floor area ratio. Construction of an additional unit resulting in a detached duplex development condition is permitted by right in this zoning district.
5. EXISTING SITE
The site is developed with structures that are contributing historic resources to the Old Towne Historic District. The residence and garage were constructed in 1919 in the Craftsman Bungalow style. The property retains a high degree of historic integrity of setting, design, materials, and craftsmanship. The property has minimal front and rear yard landscaping, consisting of a grass lawn and small shrubs.
6. EXISTING AREA CONTEXT
The subject property is located on the east side of S. Grand Street, mid-block between E. La Veta Avenue and E. Toluca Avenue. The house is located in the Nutwood Tract/Nutwood Place neighborhood. The neighborhood has a mix of duplex and mutli-family zoning. Properties on the east side of S. Grand Street are single-family residential and properties on the west side are a mix of single-family and duplex residential. All adjacent properties are zoned R-2-6.
7. analysis and statement of the issues
At the June 15, 2022 DRC meeting Committee members commented on the following items:
• Relationship of the project design to the Secretary of Interior Standards and National Park Service Historic Preservation Briefs related to new construction.
• Visibility of the unit from the street and implications on the historic streetscape and residential development pattern.
• Size of new unit in relation to the original historic structure, and particularly the need for new unit to be more subordinate to the historic structure.
• Floor area ratio in relation to the surrounding neighborhood and larger historic district neighborhoods.
• Privacy concerns related to the upper floor dormer windows and surrounding residential properties.
• Separation between historic residence and new unit with respect to interpreting the original structure’s relationship to the site.
• Placement of unit related to visibility from the street.
• Need for study of the eave projections in relation to the historic residence
• The use of fiberglass as opposed to wood windows.
• Amount of concrete in on the site associated with the driveway and garage access for the new unit.
• Treatment of side yard area on the south and the manner in which the pathway leading to the new unit disrupts the established streetscape condition and adds concrete to the site.
• Historic connection between the buildings and landscape.
• Consideration of cumulative impacts of infill development to the residential character of the historic district.
• The relationship of the South Grand Street Study to the Nutwood Tract.
The DRC Staff report and minutes are provided as Attachments 3 and 4 to this report.
In response, the applicant made the following changes to the project:
• The overall size of the unit (including garage) has been reduced from 1,620 sq. ft. to 1,224 sq. ft. making the new unit subordinate in floor area to the main residence (1,796 sq. ft.).
• The FAR was reduced from .53 to .47.
• Roof height has been lowered from 21’ to 19’2” to make the new unit more visually subordinate to the original 22’5” tall historic structure.
• The floorplan has been revised to have only one bedroom and one bathroom upstairs, allowing the elimination of the street-facing dormer and one of the rear-facing dormers. To address privacy concerns, the remaining dormer includes a small bathroom window.
• Floorplan modifications to the upper level allow for a single-story roof form at a height of 16’1” to differentiate and establish a subordinate relationship between the unit and primary residence.
• The unit has been moved 2’10” farther away from the main residence from 11’7” to 14’5” to create a greater separation from the primary residence.
• The south end of the new unit has been brought in 3’ further to the north from 5’ to 8’ to minimize its visibility from the street.
• The roof overhang has been reduced on the new unit to 1’4” to be subordinate to the 2’6” overhang on the main residence.
• The roof rake detail has been modified to include a fascia board at the eave to conceal roof rafters, differentiate between the main residence and the new residence, and reinforce the prominent appearance of the existing roof overhang.
• The proposed window material has been changed from fiberglass to wood.
• The outlooker beams and the gable roof vents have been removed from the new unit to simplify the detailing and maintain a subordinate design hierarchy.
• The new walkway leading from the street to the unit has been eliminated, allowing the existing fence along the south side of the house to remain in place.
The project is in compliance with the OMC Sections 17.14.070 and 17.34.060, providing code required setbacks, parking, and open space for each unit. However, staff is seeking confirmation from the DRC on compliance with the applicable Historic Preservation Design Standards for Old Towne (Design Standards) regarding compatibility of infill construction and non-contributing buildings within the context of the neighborhood (Attachment 7).
Issue 1. Mass, Bulk and Scale of New Unit
The infill construction standards (Design Standards, Pages 46 to 48) generally state that:
“New construction should be consistent with the mass, scale, materials, height, roof form, setbacks, and pattern of windows and doors of existing buildings on the street. The site design of an historic structure is an essential part of its character. The spacing and location of buildings on each lot within an historic neighborhood usually establishes a rhythm that is essential to the character of the neighborhood. The grouping of buildings, with uniform setbacks and street features, gives each neighborhood a strong sense of place.”
Additional specific standards elaborate on this guidance, stating that new construction should be similar in scale, placement, and style to historic construction, but should also be subordinate to the primary building on the lot.
Plan modifications reduce the bulk, mass, and scale of the upper floor in relation to the historic structure. The reduced floor area, height and elimination of dormers better achieves a subordinate relationship and design hierarchy between the historic structure than the original design proposal for the new unit.
The additional building separation and reduced visibility from the Grand Street streetscape improves the integration of the unit into the historic single-family development pattern along S. Grand Street.
Staff is seeking confirmation from the DRC on whether the design modifications achieve consistency with the infill construction standards of the Design Standards.
Issue 2. Floor Area Ratio
The Design Standards provide the following guidance for infill construction in the historic district:
“Properties with new construction are recommended to use the average Floor Area Ratio of historic properties on the surrounding street as a model for compatible new development.” (Infill Construction, 2.b.)
The average FAR on the 500-block of South Grand Street is 0.35. Despite the fact that the block features a number of larger single-family residences, the proposed 0.47 FAR would be the highest on the block for a historic property. The applicant has compiled a table with estimated FAR information for all properties on this block, included on Sheet 1 of Attachment 2. A summary of the information for historic properties is provided below.
|
Address |
FAR |
|
505 S. Grand Street |
0.40 |
|
520 S. Grand Street |
0.45 |
|
529 S. Grand Street* |
0.17 (0.30)* |
|
536 S. Grand Street |
0.44 |
|
545 S. Grand Street |
0.33 |
|
552 S. Grand Street |
0.33 |
|
Average |
0.35 (0.37)* |
|
Note: 504/512 S. Grand Street is a non-contributing property. It is highlighted as contributing on the Historic Preservation Viewer due to the historic Nutwood Place stone marker located adjacent to the property. *529 has been approved to increase the FAR to 0.30 |
While the maximum allowable FAR in the R-2-6 zone is 0.70 the Design Standards consider FAR as one of a number of factors that may affect compatibility of a project. Projects with a higher than average FAR may still meet the required Design review findings if the mass, scale, siting, and visibility of the project are appropriate for the historic district.
Staff requests direction from the DRC on whether the design modifications achieve consistency with the infill construction standards of the Historic Preservation Design Standards.
Issue 3. Privacy
Staff believes that the reduction in the number of dormers minimizes the potential for privacy impacts to surrounding properties associated with upper floor windows. A condition of approval (Condition #7) is included in Attachment 6 that requires the use of obscured glass in the rear-facing dormer window to address any remaining privacy concerns.
8. ADVISORY BOARD RECOMMENDATION
None.
9. PUBLIC NOTICE
Pursuant to Orange Municipal Code (OMC) Section 17.08.040, on or before October 7, 2022, the City sent a public meeting notice to a total of 83 property owners and occupants within a 300-foot radius of the project site. The project site was posted in one location with a notification sign on the same date.
10. ENVIRONMENTAL REVIEW
The proposed project is categorically exempt from the provisions of the California Environmental Quality Act (CEQA) per State CEQA Guidelines 15303 (Class 3 - New Construction) because the project consists of construction of a new duplex residential unit in a residential zone, with the total number of units below the maximum allowable in the R-2-6 zone.
11. STAFF RECOMMENDATION AND REQUIRED FINDINGS
Findings for DRC applications come from four sources:
• The Orange Municipal Code
• The Infill Residential Design Guidelines
• The Historic Preservation Design Standards for Old Towne (commonly referred to the Old Towne Design Standards or OTDS)
• Orange Eichler Design Standards (or OEDS)
The Findings are applied as appropriate to each project. The Design Review Committee must make the following Findings and statements in support of such Findings, with recommended conditions of approval. Staff has not made a recommendation for this project, therefore the recommended findings have not been provided for consideration.
Design Review
• In the Old Towne Historic District, the proposed work conforms to the prescriptive standards and design criteria referenced and/or recommended by the DRC or other reviewing body for the project (OMC 17.10.070.G.1).
• In any National Register Historic District, the proposed work complies with the Secretary of the Interior’s standards and guidelines (OMC 17.10.07.G.2).
• The project design upholds community aesthetics through the use of an internally consistent, integrated design theme and is consistent with all adopted specific plans, applicable design standards, and their required findings (OMC 17.10.07.G.3).
Minor Site Plan Review
• That the project design is compatible with surrounding development and neighborhoods (OMC 17.10.060.H.1).
• That the project conforms to City development standards and any applicable special design guidelines or specific plan requirements (OMC 10.12.060.H.2).
• That the project provides for safe and adequate vehicular and pedestrian circulation, both on-and off-site (OMC 17.10.060.H.3).
• That City services are available and adequate to serve the project (OMC 17.10.060.H.4).
• That the project has been designed to fully mitigate or substantially minimize to a level of insignificance potential adverse environmental effects (OMC 17.10.060.H.5).
12. CONDITIONS
Since staff has not made a recommendation on this project, no conditions of approval have been provided. Should the DRC approve the project, conditions of approval have been provided for reference as Attachment 6 of this report.
13. ATTACHMENTS
• Attachment 1 - Vicinity Map
• Attachment 2 - Revised Architectural Plans (dated July 12, 2022)
• Attachment 3 - Design Review Committee Minutes, June 15, 2022
• Attachment 4 - Design Review Committee Staff Report, June 15, 2022
• Attachment 5 - DPR Form for 515 S. Grand Street
• Attachment 6 - Draft Conditions of Approval
• Attachment 7 - Excerpt from the Historic Preservation Design Standards for Old Towne, “Infill Construction”